When designing the CAN interface, there is often a 120 Ω resistor connecting CAN_H and CAN_L on the schematic diagram, and 0.25 W is often written in the material table. These two numbers answer different questions: 120 Ω primarily addresses signal reflections; the power rating is chosen based on the actual voltage and fault conditions the resistor will withstand. This article discusses the common high-speed CAN/CAN FD two-wire bus.
1. Where does 120 Ω come from?
The twisted pair composed of CAN_H and CAN_L is a transmission line in front of rapidly changing signals. When the signal propagates along the cable, what you see is the differential characteristic impedance of the cable, not just the DC resistance measured by the multimeter. Common high-speed CAN wiring uses cables with a differential characteristic impedance of about 120 Ω. Therefore, a resistor close to this impedance at the end of the main line allows the energy reaching the endpoint to be absorbed and reflection is reduced.
Reflection can be understood by a simplified formula: reflection coefficient Γ = (Rₜ − Z₀) / (Rₜ + Z₀). where Z₀ is the differential characteristic impedance of the cable and Rₜ is the terminal resistance. Assume Z₀ = 120 Ω: When 120 Ω is connected, Γ = 0, and ideally there will be no reflection at the end; when the end is open, Γ approaches +1, and the reflection will be obvious. Real networks are also affected by spur lines, connectors, cabling and transceivers, and terminal matching does not eliminate all ringing.
Why put two, and only at both ends?
A cable has two physical endpoints, and signals may originate from either node and propagate to both sides, so terminations are required at both ends. The intermediate node should be led out from the main line at a short distance, and an additional 120 Ω should not be connected just because one more node is connected. Installing multiple terminals will reduce the equivalent resistance, increase the bus load, increase the drive current, and may also reduce the differential amplitude.
The routine check method is: after all devices are powered off, measure about 60 Ω between CAN_H and CAN_L, because two 120 Ω terminals are connected in parallel, that is, 120 Ω ∥ 120 Ω = 60 Ω. The 60 Ω here is the equivalent DC resistance of the entire bus, which does not mean that each terminal should be changed to 60 Ω. If the equipment has internal switchable terminals, split terminals or other parallel circuits, the measured values must be judged based on the actual circuit.
2. How is 0.25 W calculated?
The heating of the terminating resistor is determined by the differential voltage across it and not directly by the car's 12 V or the device's 24 V supply voltage. The calculation formula is P = Vdiff² / R.
Taking a single 120 Ω terminal as an example, assuming 2 V across the resistor in the dominant state, the instantaneous power is approximately 2² / 120 = 0.033 W, or 33 mW. At 3 V continuously, the power is approximately 75 mW. Therefore, at these example normal voltages, the 0.25 W device has some headroom. The actual average power consumption is also related to the time occupied by the dominant bit, but the selection cannot only rely on "low average traffic", but should consider the state that may continue to be dominant.
| The continuous differential voltage across the resistor | 120 Ω resistor dissipates power | meaning |
|---|---|---|
| 2 V | 0.033 W | Normal working calculation example |
| 3 V | 0.075 W | Higher Differential Voltage Example |
| 5 V | 0.208 W | Close to 0.25 W rating |
| 12 V | 1.20 W | Example of fault condition, 0.25 W is clearly not enough |
Therefore, 0.25 W is not a fixed power specified by the CAN protocol. It is just one of the common, easy-to-select ratings. Normal operating and fault conditions are evaluated separately; a 0.25 W resistor may not be able to withstand certain short circuit conditions.
What about split terminals?
Some designs split 120 Ω into two 60 Ω in series, and the midpoint is connected to the reference ground through a capacitor to improve common mode noise. The two resistors still add up to 120 Ω. If the differential voltage across CAN_H and CAN_L is 2 V, after ideal equalization, each can withstand 1 V, and their respective power is 1² / 60 ≈ 16.7 mW; the two total about 33 mW. When selecting power, each 60 Ω resistor must be calculated separately, and "0.25 W × 2" cannot be regarded as sufficient under any fault.
3. Follow these four steps for actual selection
- Confirm the topology: Install terminals only at the two physical endpoints of the trunk line, and confirm whether the device has built-in switchable terminals.
- Confirm the resistance value: Select the terminal according to the differential characteristic impedance of the cable used and the transceiver and system design requirements; common high-speed CAN uses 120 Ω at each end.
- Calculate normal power consumption: Calculate P = V² / R using the differential voltage that may appear across the resistor, and view the derating curve of the resistor under actual ambient temperature and PCB pad conditions.
- Evaluate faults individually: If required to withstand faults such as short circuit to power supply, short circuit between lines, etc., calculate according to the voltage, current and duration that the resistor in the fault circuit may withstand; also check the pulse capability and maximum operating voltage of the device.
One sentence to remember: 120 Ω is for matching transmission lines; 0.25 W is just a common power option. The former looks at cables and topology, and the latter looks at voltage, temperature, time and fault requirements.
Contact us to discuss your requirements
Whether you need a standard resistor or a custom solution for a specialized industrial application, our team is ready to help. Contact us for detailed advice, technical consultation, or a factory visit.