RELIABLE BY DESIGN
ENS-1205DC
Brand: INLANX
Description: ENS-1205DC Battery Charge/Discharge Tester. Please refer to the uploaded datasheet for detailed technical specifications and operating conditions.
Resistance, power rating, tolerance, TCR, package, lead length, mounting method, and labeling and packaging can all be customized.
Product series across the site can serve as alternatives to EBG, HVR, Vishay and other brands. Customers must verify samples and specifications before using replacement models in volume.
Total stock: 100
- Size
- 455*260*280mm
- Technology
- PTC
- Series
- ENS-1205DC Battery Charge/Discharge Tester
- Brand
- INLANX
Description: ENS-1205DC Battery Charge/Discharge Tester. Please refer to the uploaded datasheet for detailed technical specifications and operating conditions.
Total stock: 100
Brand: INLANX
Product details
Product description
For battery-group charge/discharge, activation and maintenance testing. Records group and individual-cell voltages, charge/discharge current, time and capacity to assess energy-storage performance and load capacity.
Technical features
- Load source: custom nickel-chromium alloy resistors with low resistance and high power density; resistance accuracy can be controlled within ±0.001 Ω; low temperature coefficient and high-current surge capability.
- Intelligent control: adjusts the load as battery voltage changes to maintain constant-current discharge; acquires cell voltages in real time, displays curves, analyzes voltage status and supports multiple configurable judgment thresholds.
- Discharge testing: with the battery group offline, supports constant-current or constant-power discharge through the internal load, or constant-current discharge in parallel with user equipment. Voltage, current, time and capacity thresholds can be set, and discharge parameters can be modified during testing.
- Discharge termination: stops at the group cutoff voltage, capacity or time limit, when any cell voltage falls below its configured lower limit, or on manual termination; records group voltage, cell voltage, current, time and discharged capacity.
- Automatic charging: follows constant current → constant voltage with tapering current (equalization regulation) → automatic transition to trickle/float charging, for battery charging recovery and maintenance.
- Touch operation: 7-inch high-brightness TFT resistive touchscreen, 1024×600 resolution, with direct on-screen operation.
- Wireless cell monitoring (optional): LoRa modules support 2V, 4V, 6V and 12V cells; each module monitors 6 cells simultaneously. The source example uses 4 modules for a 48V battery group.
- Cell-data analysis: displays cell voltages in real time during charging and discharging, with bar charts and data tables; automatically identifies the highest- and lowest-voltage cells to analyze trends.
- Curves and reports: reviews battery-group voltage and current curves; supports USB-drive data transfer, with analysis software parsing the data and generating reports.
Technical specifications
| Discharge voltage | 2-120 VDC |
|---|---|
| Discharge current | 2-90 V:0-50 A91-120 V:0-37.5 A |
| Charge voltage | 2-120 VDC |
| Charge current | 2-60 V:0-50 A61-120 V:0-25 A |
| Power limits | Discharge 4.5 kW; charge 3 kW |
| Dimensions (length × width × height) | 455 × 260 × 280 mm |
| Main-unit mass | Approx. 16.3 kg |
| AC supply | Single-phase AC220V, 40-60Hz |
| Operation | Touchscreen |
| Display | 7-inch TFT LCD, resistive touch, 1024×600 |
| Data communication | 1×RS485 |
| Internal storage | 128 Mbit FLASH |
| Voltage measurement accuracy | ±0.5%FS + 0.1 V |
| Current measurement accuracy | ±1%FS + 0.1 A |
| Group voltage display accuracy | 0.1 V |
| Group current display accuracy | 0.1 A |
| Discharge current control accuracy | ±1%FS |
| Main-unit protection | Shutdown on overtemperature, overcurrent or loss of current control |
| Shutdown device | High-voltage DC switch |
| Reverse-polarity protection | Supported |
| Abnormal-condition protection | Power loss at the power cable or main cable |
| Overtemperature thresholds | Resistor enclosure 85°C; heatsink 100°C |
| Alarm | LCD indication and buzzer |
| Cooling | Forced-air cooling |
| Operating temperature | -5 to +50°C |
| Storage temperature | -40 to +70°C |
| Relative humidity | 0-90% RH (40±2°C) |
| Rated altitude | 2000 m |
Applications and selection
- Suitable for battery and UPS power-supply maintenance.