RELIABLE BY DESIGN
78KW-AC380V/AC480V
Brand: INLANX
Description: INLANX-78KW-AC380V/AC480V dual-circuit dual-voltage air-cooled load bank is used for air-cooling testing in data equipment rooms and power system load verification to simulate real loads. Dual independent inputs and independent controls enable dual independent testing. No N-phase power connection is available, adapting to various on-site power supply conditions. Suitable for IDC computer room, UPS/generator, power distribution system and industrial equipment testing.
Resistance, power rating, tolerance, TCR, package, lead length, mounting method, and labeling and packaging can all be customized.
Product series across the site can serve as alternatives to EBG, HVR, Vishay and other brands. Customers must verify samples and specifications before using replacement models in volume.
Total stock: 100
- Size
- 600*1800*900 mm
- Rated power
- 78000 W
- Tolerance
- ±10%
- TCR
- 400 ppm
- Technology
- Metal tube / wirewound
- Series
- 78KW-AC380V/AC480V dual-channel dual-voltage air-cooled load bank
- Brand
- INLANX
Description: INLANX-78KW-AC380V/AC480V dual-circuit dual-voltage air-cooled load bank is used for air-cooling testing in data equipment rooms and power system load verification to simulate real loads. Dual independent inputs and independent controls enable dual independent testing. No N-phase power connection is available, adapting to various on-site power supply conditions. Suitable for IDC computer room, UPS/generator, power distribution system and industrial equipment testing.
Total stock: 100
Brand: INLANX
Product details
Product description
For data-center air-cooling tests and power-system load validation, simulating real loads.
Technical features
- Two independently controlled inputs, each rated 39KW with total power 78KW; compatible with AC380V /AC480V dual voltage for different site supplies.
- Separate meters for both inputs display voltage, current, power and power factor in real time; three-phase stepped adjustment, starting at 3KW.
- Three fans provide forced-air cooling with adjustable airflow; high-quality alloy resistors offer high-temperature resistance, long life and stable performance.
- Two independent inputs with independent control for separate tests.
- Can connect without an N conductor to suit different site supplies.
Technical specifications
| Product name | Dual-input, dual-voltage air-cooled load bank |
|---|---|
| Model | 78KW-AC380V/AC480V |
| Total power | 78KW |
| Power per input | 39KW × 2 |
| Input voltage | AC380V / AC480V |
| Input arrangement | Two inputs with independent control |
| Wiring | Operation without an N connection |
| Power adjustment | Three-phase stepped adjustment, starting at 3KW |
| Display | Separate displays for both inputs: voltage, current, power, power factor |
| Cooling | Three-fan forced-air cooling; adjustable airflow |
| Resistor material | High-quality alloy resistors |
| Overall dimensions | Width W600 × height H1800 × depth D900 mm (including casters) |
Applications and selection
- Suitable for IDC equipment rooms, UPS / generator, distribution-system and industrial-equipment testing.