RELIABLE BY DESIGN
45KW+270KW
Brand: INLANX
Description: INLANX-45KW+270KW air-liquid integrated resistance load cabinet - integrates air cooling and liquid cooling, suitable for testing and aging in new energy, energy storage, charging piles, aerospace, power electronics and other fields. Total air cooling power 45KW | Total liquid cooling power 270KW | Support customization on demand
Resistance, power rating, tolerance, TCR, package, lead length, mounting method, and labeling and packaging can all be customized.
Product series across the site can serve as alternatives to EBG, HVR, Vishay and other brands. Customers must verify samples and specifications before using replacement models in volume.
Total stock: 100
- Size
- 600*2100*1200 mm
- Rated power
- 45000-270000 W
- Tolerance
- ±10%
- TCR
- 400 ppm
- Series
- 45KW+270KW combined air- and liquid-cooled load bank
- Brand
- INLANX
Description: INLANX-45KW+270KW air-liquid integrated resistance load cabinet - integrates air cooling and liquid cooling, suitable for testing and aging in new energy, energy storage, charging piles, aerospace, power electronics and other fields. Total air cooling power 45KW | Total liquid cooling power 270KW | Support customization on demand
Total stock: 100
Brand: INLANX
Product details
Product description
HAC-315 integrates air-cooled and liquid-cooled resistive elements in one floor-standing cabinet to precisely simulate next-generation AI cabinets (such as INLANX GB200 / GB300 NVL72): fans remove part of the heat, while direct cold-plate/immersion liquid cooling removes the remainder. The air-cooled and liquid-cooled sections are independently adjustable to verify PDU three-phase current balance, CDU flow and chiller capacity under actual hybrid heat-dissipation conditions.
Technical features
- Air-cooled section 45kW: Simulates fan heat discharge from conventional CRAH / air-cooled servers.
- Liquid-cooled section 270kW: 2 immersion stainless-steel resistive heating vessels provide high-density heat dissipation.
- Independent control of air-cooled/liquid-cooled sections for realistic hybrid-load simulation.
- Quick-connect input panel: Color-coded N/A/B/C phases for rapid on-site connection and disconnection.
- 304 stainless-steel piping and resistive elements, pickled and passivated for corrosion resistance.
- Touchscreen HMI: Full parameter display and data export.
- Manual / programmable dual modes: Local switches or touchscreen automatic loading/unloading sequences.
- Customization available: Power, voltage, steps, interfaces and cooling medium can be customized as required.
Technical specifications
| Product type | Air/liquid-cooled resistive load cabinet, floor-standing cabinet |
|---|---|
| Total air-cooled power | 45kW (upper air-cooled section, height 500mm) |
| Total liquid-cooled power | 270kW (lower liquid-cooled section, height 1500mm) |
| Total unit power | 315kW |
| Rated voltage | AC 380V / 400V / 415V / 480V (customizable), three-phase |
| Overall dimensions | Width 600 × height 2100 × depth 1200 mm |
| Connection method | Quick-connect plugs, color-coded N/A/B/C/ground; customizable as required |
| Control method | Manual local / touchscreen programmable control |
| Material | 304 stainless steel, pickled and passivated |
| Protection functions | Dry heating, short circuit, low flow, overtemperature, overcurrent, phase loss/phase sequence, overvoltage/undervoltage, emergency stop |
| Air-cooled section | Voltage, current, active power, power factor |
| Liquid-cooled section | Voltage, current, power, flow, inlet/outlet water temperature, temperature difference, inlet/outlet water pressure, pressure difference |
Applications and selection
- AI cabinet (GB200/GB300) thermal simulation, data-center level-five acceptance testing, energy storage BESS inverter testing, charging-pile / charging-module testing, aerospace power-supply verification, and microgrid / virtual power plant verification.