Description: The INLANX 168 kW AC/DC load bank combines three 48 kW liquid-cooled modules with two 12 kW air-cooled modules. It supports AC 220 V and DC 270 V testing with centralized, manual or programmable loading for data centers, power systems, energy storage and charging systems.
Resistance, power rating, tolerance, TCR, package, lead length, mounting method, and labeling and packaging can all be customized.
Product series across the site can serve as alternatives to EBG, HVR, Vishay and other brands. Customers must verify samples and specifications before using replacement models in volume.
Total stock: 100
- Size
- 600*2300*1200 mm
- Rated power
- 168000 W
- Tolerance
- ±10%
- TCR
- 400 ppm
- Series
- 168KW combined AC/DC liquid- and air-cooled load bank
- Brand
- INLANX
Description: The INLANX 168 kW AC/DC load bank combines three 48 kW liquid-cooled modules with two 12 kW air-cooled modules. It supports AC 220 V and DC 270 V testing with centralized, manual or programmable loading for data centers, power systems, energy storage and charging systems.
Total stock: 100
Brand: INLANX
Product details
Product description
The INLANX 168kW AC/DC liquid-cooled + air-cooled load cabinet is a modular hybrid load system designed for testing in data centers, powersystems, energy storage systems and charging systems. It supports AC220V and DC270V testing, centralized control, manual loading andprogrammed loading. Load capacity can be configured flexibly to meet the needs of server rooms and test scenarios of different sizes.
Technical features
- • Standard configuration: 3×48kW liquid cooling + 2×12kW air cooling, total power 168kW
- • AC/DC compatible: AC220V / DC270V
- • Control: programmed + manual
- • One-touch loading: 25% / 50% / 75% / 100%
- • Automatic AC/DC program identification
- • PTC heating material
- • Flexible combinations for different server-room test capacities
- • Separate cabinet/module procurement with unified data integration
- • Custom electrical interfaces: Harting 7PIN, Harting 5PIN, industrial connectors 63A, Amphenol plug-strip connectors, etc.
- • Modular combinations: flexible configuration to meet demand
- • One-touch loading: fast multi-stage loading and convenient operation
- • Flexible expansion: maximum 240kW for future needs
- • Integrated data: centralized control and unified data management
- • Hybrid liquid + air cooling: efficient heat dissipation and reliable stability
- • Custom interfaces: industrial interface options for different applications
Model table
| Model |
|---|
| INLANX-168kW |
Technical specifications
| Standard Configuration | 3×48kW liquid cooling + 2×12kW air cooling; total 168kW |
|---|---|
| Expandable Configuration | Up to 4×48kW liquid cooling + 4×12kW air cooling; maximum 240kW |
| Enclosure Dimensions | W600 × H2300 × D1200 mm |
| Voltage Mode | AC220V / DC270V compatible |
| Control | Programmed + manual |
| One-Touch Loading | 25% / 50% / 75% / 100% |
| Loading steps | AC single-phase 1kW/ step; AC three-phase 3kW/ step; DC270V 1kW/ step |
| Load Material | PTC heating material |
| Electrical Acquisition | Voltage, current and power |
| Liquid-Cooling Acquisition | Inlet temperature, outlet temperature, pressure, flow, differential pressure and temperaturedifference |
| Data Functions | Data acquisition, display, storage and export |
| Module Structure | Module-level acquisition with system-wide data integration |
| Custom interfaces | Custom electrical connections: Harting 7PIN, Harting 5PIN, industrial connectors 63A, Anfei plug-strip connectors, etc. |
| Application Features | Flexible combinations for different data-center test capacities |
| Liquid Circuit Valves | Each module has an individual valve. The water circuit can be shut off at any time to adjustthe flow of each circuit. |
| PTC material characteristics | 1. Self-limiting temperature characteristics for safe, reliable operation2. Quasi-constant-power regulation3. Resistance increases with temperature4. Stable and durable for liquid-cooling system testing |
| Acquisition and display | • Electrical acquisition: voltage, current and power• Liquid-cooling acquisition: inlet and outlet temperatures, pressure,flow, differential pressure and temperature difference• Data functions: real-time display, storage, export and analysis |
| Multiple protection functions | Multiple safeguards protect the equipment and ensure safe, reliabletesting.1. Dry-running protection (low-flow / interrupted-flow interlock)2. Over-current protection3. Short-circuit protection4. High outlet-temperature protection5. Over-voltage protection6. Overload protection7. Grounding protection8. Leak detection / liquid leakage protection |
Applications and selection
- The INLANX 168kW AC/DC liquid-cooled + air-cooled load cabinet uses a modular hybrid load system with module-level acquisition andsystem-wide data integration. It provides flexible configuration, programmed and manual control, one-touch loading, comprehensiveacquisition and protection. It meets load-testing needs in data centers, power systems, energy storage and charging stations. Electricalconnection interfaces can be customized to provide professional, reliable and efficient test solutions.